Abstract

Fluorine (F) plays an important role in dental health and bone formation. Many studies have shown that excess fluoride (F−) can result in dental or skeletal fluorosis, while other studies have indicated that a proper dosage of fluoride may have a protective effect on bone fracture incidence. Fluorine is stored almost completely in the skeleton making bone an ideal site for measurement to assess long-term exposure. This paper outlines a feasibility study of a technique to measure bone-fluorine non-invasively in the human hand using in vivo neutron activation analysis (IVNAA) via the 19F(n,γ)20F reaction. Irradiations were performed using the Tandetron accelerator at McMaster University. Eight NaI(Tl) detectors arranged in a 4π geometry were employed for delayed counting of the emitted 1.63 MeV gamma ray. The short 11 s half-life of 20F presents a difficult and unique practical challenge in terms of patient irradiation and subsequent detection. We have employed two simultaneous timing methods to determine the fluorine sensitivity by eliminating the interference of the 1.64 MeV gamma ray from the 37Cl(n,γ)38Cl reaction. The timing method consisted of three counting periods: an initial 30 s (sum of three 10 s periods) count period for F, followed by a 120 s decay period, and a subsequent 300 s count period to obtain information pertaining to Ca and Cl. The phantom minimum detectable limit (MDL) determined by this method was 0.96 mg F/g Ca. The MDL was improved by dividing the initial timing period into three equal segments (10 s each) and combining the results using inverse variance weighting. This resulted in a phantom MDL of 0.66 mg F/g Ca. These detection limits are comparable to ex vivo results for various bones in the adult skeleton reported in the literature. Dosimetry was performed for these irradiation conditions. The equivalent dose for each phantom measurement was determined to be 30 mSv. The effective dose was however low, 35 µSv, which is comparable to other clinical diagnostic tools. The MDL, relatively low radiation dose and non-invasiveness indicate the suitability of this method for routine in vivo analysis of bone-fluorine content. This prompted us to perform a trial study in human subjects. A preliminary human study on 34 participants was completed, with 33 of the 34 measurements proving to be successful. The in vivo MDL based on the improved timing method was determined to be 0.69 mg F/g Ca for the 33 successful human measurements. In our opinion, this technique has been demonstrated to be a suitable method for in vivo assessment of fluorine bone-burden.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.