Abstract
Electrofusion jointing is a common joint process used to weld polyethylene (PE) water pipe in the UK. For many years, the UK Water Industry has experienced a small number of premature failures of electrofusion fittings; this inevitably causes leakage. The common causes of critical failures have been highlighted and as a result of this, a testing programme was designed and implemented to assess the fatigue performance of electrofusion tapping tees if they were to be installed by ‘bad practice’. A fine china talc was used to replicate contamination in the field. The results suggest that failures associated with fatigue are possible in a relatively short space of time on tapping tees when they are subject to contamination. The pressure ranges used in the fatigue regime aimed to replicate the potential magnitude of surge pressures that can be experienced in water distribution mains.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal of Pressure Vessels and Piping
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.