Abstract

Abstract A kilowatt order CW and transverse electrical (TE) discharge CO2 laser has been designed and fabricated. The optimum discharge conditions (e.g., the mixing pressure ratio of gases, the total pressure and the discharge current etc.), the factors affecting the output stability, and the long time sealing condition have been investigated. When the mixing ratio of gases is CO2:CO:N2:He=6:3:30:80, the total pressure is 110 torr, and the discharge current is 4.2 A, the maximum output power of 1,100 W and the laser efficiency of 17.2% are obtained. The system can be operated continuously for 9 hours with the maximum power fluctuation of 2% under the sealed condition. Therefore, it can greatly reduce the operational cost. All the controllers (including gas inlet components, vacuum components, power supply, cooling machine, shutter and the NC x—y table and indicators, e. g., pressure gauge, discharge voltage and interlocks) are mounted at a control panel and can be operated easily. The laser system shall b...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.