Abstract

This paper describes recent progress in the development of Nb/sub 3/Sn wires in Switzerland using the internal tin method. The work was carried out in close collaboration between the Fusion Technology Division of CRPP and Swissmetal, with the emphasis on conductors suitable for fusion magnets. The manufacturing process is based on the tubular extrusion of a niobium-copper composite, followed by the cold working of the composite containing a tin core. 19 Nb-Cu-Sn subelements were assembled inside a tantalum diffusion barrier and a copper can and subsequently reduced to wire size by swaging and drawing. The intention was to obtain non-reacted filament sizes of typically 3 /spl mu/m in 0.8-1 mm wires. The evolution of the design and the manufacturing process are discussed. Experience gained with model conductors has been used to guide the design. The strands have been evaluated with respect to electrical and mechanical properties. In particular, critical current densities in the non-copper area exceeding 750 A/mm/sup 2/ at 12 T and 4.2 K have been achieved.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.