The EyeSys videokeratoscope was used to assess the corneal topography in 98 subjects. Scatterplots of distance squared versus radius squared were plotted for the near horizontal and near vertical principal meridians of the two eyes. The regression lines allowed calculation of the surface apical radius and the p-value. The group average apical radius was 7.93 mm (horizontal) and 7.78 mm (vertical). The group average p-value was 0.76 (horizontal) and 0.82 (vertical). Both apical radius and p-value were similar when comparing the two eyes for both the horizontal and the vertical meridians. The two meridians in a single eye, however, had different values for both apical radius and p-value. Male apical radii were longer than those of females but the p-values were the same. There is no apparent association between age and either apical radius or p-value for the subjects used in this study. The asphericity of the cornea does not show any apparent association with corneal curvature in this group of subjects.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.