Abstract

As one of the key components of Sector Focusing Cyclotron at the Institute of Modern Physics, Chinese Academy of Sciences, the electrostatic deflector can be activated by primary and secondary particles, because of a mismatch between the actual value and the design value of the emittance and emergence angle. In addition, it will be struck by more particles, since there is a stray magnetic field and outgas from the surface of the electrostatic deflector. The residual radioactivity in the electrostatic deflector has been studied in two aspects: specific activity and residual dose rate, based on the gamma-ray spectrometry and Fluke 451p ionization chamber, respectively. The specific activity of radionuclides in the main components and the dust on the enclosure have been investigated by using gamma-ray spectrometry. The residual dose rate around the electrostatic deflector has been obtained by Fluke 451p ionization chamber. The results of the study show that there is a non-negligible radiological risk to the staff. This result can be provided as guidance for making a maintenance schedule, so that the dose received by staff can be kept as low as reasonably achievable. Based on the results, advice for "hands-on" maintenance and decommissioning of the SFC have been provided.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.