Abstract

We have developed a proof-of-concept low power free electron maser that is compact and low cost. The design, set-up and results of a novel (without wiggler) low power X-band rectangular waveguide pre-bunched free electron maser (PFEM) are presented in this paper. Our device operates at 10GHz, with 10mWatt seeding input power and employs two rectangular waveguide cavities (one for velocity modulation and the other for energy extraction). The electron beam used in this experiment is produced by Thoria coated Iridium fllament which can operate at 3kV and up to 5mA beam current. The efiect of the aperture on the power leaking out of the waveguide is also analyzed. The TE10 mode propagation of the EM standing wave is used to pre-bunch the electron beams in the input cavity. The bunched electron beams are in the same phase as the TE10 mode propagation of the EM wave in the output cavity. This free electron maser could be useful industrially, as it could be used with the commercially available accelerating voltage supplies.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.