The paper designed three joints namely beam-column joint of reinforced concrete frame without slab and two beam-column joints of reinforced concrete frame with slab, using different loading methods (one direction and two directions) to experiment. The paper studied failure behavior, load-carrying capacity, and slab participation in flexural behavior of beam under different loading modes. Experiment shows that for the joints with slab, flexural capacity at end of the beam under two direction loads than one direction loads lows by about 10%; under one direction load, effective flange width of slab should be taken 8 times thickness, under two direction loads, effective flange width of slab should be taken 10 times thickness.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.