Abstract

The purpose of this study was to explore the endoscopic endonasal approach to the anterior communicating artery complex. Anatomic, morphometric analysis of human cadaver heads. Fifteen latex-injected adult cadaver heads. The anatomic boundaries of the operative field and the dimensions of exposure of the anterior communicating artery (ACoA) complex were measured and clip placement feasibility was assessed. Exposure of the ACoA and bilateral A1 and A2 segments was accomplished in all 15 cadaver heads. Average length of the exposed ACoA was 3 ± 1 mm, the left A1 was 5 ± 3 mm and right A1 was 5 ± 1 mm, while the A2 segment was 5 ± 2 mm bilaterally. The average distance from the alar floor to the ACoA was 95 mm, while proximal lateral limit measured between the alar floor margins was 36 mm. The distal lateral limit as defined by the distance between the lateral most exposed margins of the chiasm was 19 mm. Clip placement was accomplished for the ACoA and the A1 and A2 segments bilaterally in all specimens. The endoscopic, endonasal transtuberculum, transplanum approach is an anatomically feasible alternative to treating select aneurysms of the ACoA complex.