Abstract

BackgroundOur research compared whole pelvic (WP) and prostate-only (PO) 3-dimensional conformal radiotherapy (3DCRT) techniques in terms of the incidence and evolution of acute and late toxicity of the rectum and urinary bladder, and identified the PTV-parameters influencing these damages and changes in antitumor immune response.MethodsWe analyzed 197 prostate cancer patients undergoing 3DCRT for gastrointestinal (GI) and genitourinary (GU) toxicities, and conducted a pilot immunological study including flow cytometry and an NK cell cytotoxicity assay. Acute and late toxicities were recorded according to the RTOG and the LENT-SOMA scales, respectively. Univariate and multivariate analyses were conducted for factors associated with toxicity.ResultsIn the WP group, an increase of acute rectal toxicity was observed. A higher incidence of late GI/GU toxicity appeared in the PO group. Only 18 patients (WP-7.76% and PO-11.11%) suffered severe late GI toxicity, and 26 patients (WP-11.21% and PO-16.05%) severe late GU toxicity. In the majority of acute toxicity suffering patients, the diminution of late GI/GU toxicity to grade 1 or to no toxicity after radiotherapy was observed. The 3DCRT technique itself, patient age, T stage of TNM classification, surgical intervention, and some dose-volume parameters emerged as important factors in the probability of developing acute and late GI/GU toxicity. The proportion and differentiation of NK cells positively correlated during 3DCRT and negatively so after its completion with dose-volumes of the rectum and urinary bladder. T and NKT cells were down-regulated throughout the whole period. We found a negative correlation between leukocyte numbers and bone marrow irradiated by 44-54 Gy and a positive one for NK cell proportion and doses of 5-25 Gy. The acute GU, late GU, and GI toxicities up-regulated the T cell (CTL) numbers and NK cytotoxicity.ConclusionOur study demonstrates the association of acute and late damage of the urinary bladder and rectum, with clinical and treatment related factors. The 3DCRT itself does not induce the late GI or GU toxicity and rather reduces the risk of transition from acute to late toxicity. We have described for the first time the correlation between organs at risk, dose-volume parameters, and the immunological profile.

Highlights

  • Our research compared whole pelvic (WP) and prostate-only (PO) 3-dimensional conformal radiotherapy (3DCRT) techniques in terms of the incidence and evolution of acute and late toxicity of the rectum and urinary bladder, and identified the Planning target volume (PTV)-parameters influencing these damages and changes in antitumor immune response

  • Other important predictors of acute GI toxicity were the percentage of rectum volume receiving 70 Gy and the 3DCRT technique used, where the high-level toxicity developed when the WP technique was used (26.16 times greater than in the case of the PO technique)

  • Another important statistically significant predictor found for late GU toxicity was the PO type of 3DCRT that evoked the development of high-level toxicity 1.72 times more (OR = 0.580) in comparison with WP technique

Read more

Summary

Introduction

Our research compared whole pelvic (WP) and prostate-only (PO) 3-dimensional conformal radiotherapy (3DCRT) techniques in terms of the incidence and evolution of acute and late toxicity of the rectum and urinary bladder, and identified the PTV-parameters influencing these damages and changes in antitumor immune response. In spite of this focus, a higher dose to the prostate implies that the surrounding organs at risk (OARs) may receive higher doses. The acute exposure to low- and high-dose irradiation in mouse models changes the quantitative and functional parameters of immune cells, due to different sensitivity of splenocyte subsets to radiation doses [9]. Radiation-induced BM injury depends on both the radiation dose and the volume of BM irradiated [14]

Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.