Abstract
Traumatic injury is the leading cause of potentially preventable lost years of life in the Western world and exsanguination is the most potentially preventable cause of post-traumatic death. With mature trauma systems and experienced trauma centres, extra-abdominal sites, such as the pelvis, constitute the most frequent anatomic site of exsanguination. Haemorrhage control for such bleeding often requires surgical adjuncts most notably interventional radiology (IR). With the usual paradigm of surgery conducted within an operating room and IR procedures within distant angiography suites, responsible clinicians are faced with making difficult decisions regarding where to transport the most physiologically unstable patients for haemorrhage control. If such a critical patient is transported to the wrong suite, they may die unnecessarily despite having potentially salvageable injuries. Thus, it seems only logical that the resuscitative operating room of the future would have IR capabilities making it the obvious geographic destination for critically unstable patients, especially those who are exsanguinating.Our trauma programme recently had the opportunity to conceive, design, build, and operationalise a purpose-designed hybrid trauma operating room, designated as the resuscitation with angiographic percutaneous techniques and operative resuscitation (RAPTOR) suite, which we believe to be the first such resource designed primarily to serve the exsanguinating trauma patient. The project was initiated after consultations between the trauma programme and private philanthropists regarding the greatest potential impacts on regional trauma care. The initial capital construction costs were thus privately generated but coincided with a new hospital wing construction allowing the RAPTOR to be purpose-designed for the exsanguinating patient. Many trauma programmes around the world are now starting to navigate the complex process of building new facilities, or else retrofitting existing ones, to address the need for single-site flexible haemorrhage control. This manuscript therefore describes the many considerations in the design and refinement of the physical build, equipment selection, human factors evaluation of new combined treatment paradigms, and the final introduction of a RAPTOR protocol in order that others may learn from our initial efforts.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.