Abstract

The applicability of a tube-type diffusive sampler as an environmental monitor for benzene, toluene, ethylbenzene and xylene (BTEX) is reported. Uptake rates have been experimentally determined for a novel type adsorbent, Tenax GR, and compared to theoretical values. It is shown, that the uptake rates are virtually independent of environmental parameters within the experimental conditions studied. The response of the sampler to transient changes in concentrations has been determined in the laboratory. It is found that the sampler is capable of following an extreme concentration profile. Field comparisons with pumped samplers have been performed and good agreement is observed between the results of the two independent methods. The samplers have also been applied as environmental monitors at different locations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.