Abstract

The emittance of positive ion beams extracted from a PIG ion source with end extraction was measured for optimal operating conditions of the source at different positions of the beam line. The source was operated with noble gases in a high voltage - low current discharge mode. The results showed that the emittances increase with increasing ion mass and intensity of the ion beam and furthermore under the influence of the space charge of the beam with the distance from the source. For ion beam intensities of 1 mA values of the emittance were obtained between 0,4 and 1,1 cm mrad MeV1/2 at a distance of 10 cm behind the extraction region. The brightness varied from 0,15 to 1,3 mA cm-2 mrad-2 MeV.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.