Abstract

We report on the technological commissioning of the Laser–Plasma Ion Accelerator section of the ELIMAIA user beamline at the ELI Beamlines facility in the Czech Republic. The high-peak, high-average power L3-HAPLS laser system was used with an energy of ~10 J and pulse duration of ~30 fs on target, both in single-pulse and high repetition-rate (~0.5 Hz) mode. The laser pulse was tightly focused to reach ultrahigh intensity on target (~1021 W/cm2) and sustain such laser–plasma interaction regime during high repetition-rate operations. The laser beam, ion beam, and laser–plasma emission were monitored on a shot-to-shot basis, and online data analysis at 0.5 Hz was demonstrated through the full set of used diagnostics (e.g., far and near field, laser temporal diagnostics, X- and gamma-ray detectors, Thomson Parabola ion spectrometer, time-of-flight ion detectors, plasma imaging, etc.). The capability and reliability of the ELIMAIA Ion Accelerator was successfully demonstrated at a repetition rate of 0.5 Hz for several hundreds of consecutive laser shots.