In this paper, electrical tree structures once after initiation are presented, and the initiation time of electrical tree at different electric field strength is recorded by the stereomicroscope under continuous voltage. Applied voltage and electrode separation are changed to obtain different field strength. Numerical calculations based on curve fitting show a certain degree of field dependence of the electrical tree initiation time, which leads to a threshold field strength at this experiment system. However, initiation time shows increased dispersion by the decrease of field strength. Even when the field strength is close to the threshold, initiation becomes random. It is inferred that threshold field strength should be considered as an approximate value based on the available experiment results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.