Abstract

ObjectiveReducing perinatal morbidity and mortality is one of the major challenges in modern health care. Analysing the ST segment of the fetal electrocardiogram was thought to be the breakthrough in fetal monitoring during labour. However, its implementation in clinical practice yields many false alarms and ST monitoring is highly dependent on cardiotocogram assessment, limiting its value for the prediction of fetal distress during labour. This study aims to evaluate the relation between physiological variations in the orientation of the fetal electrical heart axis and the occurrence of ST events.MethodsA post-hoc analysis was performed following a multicentre randomised controlled trial, including 1097 patients from two participating centres. All women were monitored with ST analysis during labour. Cases of fetal metabolic acidosis, poor signal quality, missing blood gas analysis, and congenital heart disease were excluded. The orientation of the fetal electrical heart axis affects the height of the initial T/QRS baseline, and therefore the incidence of ST events. We grouped tracings with the same initial baseline T/QRS value. We depicted the number of ST events as a function of the initial baseline T/QRS value with a linear regression model.ResultsA significant increment of ST events was observed with increasing height of the initial T/QRS baseline, irrespective of the fetal condition; correlation coefficient 0.63, p<0.001. The most frequent T/QRS baseline is 0.12.ConclusionThe orientation of the fetal electrical heart axis and accordingly the height of the initial T/QRS baseline should be taken into account in fetal monitoring with ST analysis.

Highlights

  • ObjectiveReducing perinatal morbidity and mortality is one of the major challenges in modern health care

  • Fetal asphyxia is associated with severe perinatal morbidity and mortality

  • A significant increment of ST events was observed with increasing height of the initial T/ QRS baseline, irrespective of the fetal condition; correlation coefficient 0.63, p

Read more

Summary

Objective

Reducing perinatal morbidity and mortality is one of the major challenges in modern health care. Analysing the ST segment of the fetal electrocardiogram was thought to be the breakthrough in fetal monitoring during labour. Its implementation in clinical practice yields many false alarms and ST monitoring is highly dependent on cardiotocogram assessment, limiting its value for the prediction of fetal distress during labour. This study aims to evaluate the relation between physiological variations in the orientation of the fetal electrical heart axis and the occurrence of ST events

Methods
Results
Introduction
Background information and hypothesis
Materials and methods
Results and discussion
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.