Abstract
An investigation was carried out to examine the influence of the fastener length on the elastic and ductile failure behaviour of typical steel-to-timber bracket connections in Cross Laminated Timber (CLT) manufactured from C16 spruce. The behaviour of single screw-type fasteners within CLT of length 25 mm, 50 mm and 75 mm are examined under tension and shear loading. Multiple screw-type fasteners have been utilised to examine monotonic and cyclic behaviour of steel bracket-fastened CLT connections under shear and tension loading. Characteristic values of the experimental results are compared to analytical models from current timber design codes and the literature. The length of fastener has been shown to influence the failure strength and ductility of the connection. The overstrength factors and strength degradation factors have been shown to be similar, regardless of fastener length, and conservative values are recommended.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.