Abstract

This study was conducted to investigate the efficacy of routine screening for high-frequency hearing loss (HFHL) including 3000, 6000, and 8000 Hz frequencies with conventional test frequencies (1000, 2000, and 4000 Hz) in adults and children in a university outreach program. Screening outcomes were examined in 2 cohorts of adults (Cohort 1, N = 315, M = 66.2 years; Cohort 2, N = 67, M = 68.3 years) and children (Cohort 1, N = 177, M = 6.5 years; Cohort 2, N = 57, M = 6.9 years) with a high-frequency screen protocol (1000-8000 Hz at 25 dB HL for adults and 20 dB HL for children) using supra-aural headphones. A rescreen was conducted in Cohort 2 with a modified protocol using insert earphones and monitored ambient noise levels. Average total test time significantly increased (p < .0001) and nearly doubled with inclusion of 3000-, 6000-, and 8000-Hz frequencies, adding approximately 1 min. Rescreen referral rates decreased by approximately 2%-16% at 1000-8000 Hz (approximately 13%-16% at 6000 and 8000 Hz) using the modified protocol in adults and children, supporting false-positive responses using supra-aural headphones. Screening for HFHL should include insert earphones in order to prevent potential errors, particularly at 6000 and 8000 Hz.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.