Abstract

This study evaluates the efficacy of intraoperative neuromonitoring (IONM) on voice performance in robotic thyroidectomy. The study was based on a prospective randomized series. Between June 2011 to September 2012, 50 patients with thyroid cancer who underwent robotic thyroidectomy were enrolled. The IONM and non-IONM groups consisted of 25 patients each. Voice Handicap Index (VHI), voice range profile (VRP), and laryngoscopy were used to assess voice function before surgery and at 2 weeks, 3 months, and 6 months after the operation. No palsy was diagnosed by laryngoscopy in either group. VHI values were similar in both groups. In the IONM group, there was significantly earlier recovery in VRP minimum intensity compared with the non-IONM group. However, there were no differences of mean change of VRP maximum frequency and intensity or minimum frequency between the two groups. We found that IONM facilitated more rapid recovery of voice function, especially in VRP minimum intensity, during robotic thyroid surgery.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.