Abstract

Intrauterine growth restriction (IUGR) is an important issue in perinatology. To assess the efficacy of fetal thigh volume (ThVol) in predicting IUGR, we undertook a prospective cross-sectional study using quantitative 3-D ultrasound (US). During the study period, 30 fetuses with IUGR and 282 fetuses with non-IUGR were included for the ThVol assessment in utero by 3-D US. All the fetuses were singletons and had follow-up to the delivery to determine whether they were complicated with IUGR or not. Our results showed fetal ThVol assessed by 3-D US can differentiate fetuses with IUGR from fetuses with non-IUGR well. Using the 10th percentile as the screening threshold, the sensitivity of fetal ThVol in predicting IUGR was 86.6%, with specificity 91.1%, predictive value of positive test 51.0%, predictive value of negative test 98.5% and accuracy 90.7%. In conclusion, fetal ThVol assessed by quantitative 3-D US can be used to predict fetuses with IUGR antenatally. We believe fetal ThVol assessment by 3-D US would be a useful test in detecting fetuses with IUGR. (E-mail: fchang@mail.ncku.edu.tw)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.