Abstract

Background Autologous blood transfusion is a common technique in cardiac surgery to directly re-infuse residual blood from the cardiopulmonary bypass (CPB) circuit to the patient. The objective of this study was to evaluate the effects of reinfusion of unprocessed residual pump blood on the coagulation system after separation from the CPB circuit and reversal of systemic heparin with protamine. Measurements and main results After ethics approval, 40 participants undergoing cardiac surgery were recruited in a prospective single center cohort study. Changes in coagulation were assessed with standard plasma based laboratory assays and thromboelastography. After the reinfusion of unprocessed residual pump blood there were decreases in the mean aPTT (effect size 6 s; SD: 6.05; p < 0.0001) and thrombin time (effect size 4.08 s; SD: 9.7; p = 0.01). There were no significant changes in PT, INR and D-dimer. Post reinfusion there were increases in fibrinogen, hemoglobin and platelet counts. There were improvements in the R-time (effect size 9.1 s; SD: 16.9; p = 0.0023), K-time (effect size 1.5 s; SD: 3.6 s; p = 0.0017), alpha angle (6.9°; SD: 15.8; p = 0.012), and maximum amplitude (3.0 mm; SD: 5.6, p = 0.002) on thromboelastography.ConclusionThe reinfusion of unprocessed residual CPB blood resulted in no deleterious effects on the coagulation system measured by both the common laboratory plasma based measurements of coagulation and thromboelastography.

Highlights

  • Autologous blood transfusion is a common technique in cardiac surgery to directly re-infuse residual blood from the cardiopulmonary bypass (CPB) circuit to the patient

  • The reinfusion of unprocessed residual CPB blood resulted in no deleterious effects on the coagu‐ lation system measured by both the common laboratory plasma based measurements of coagulation and thromboelastography

  • We hypothesized that the administration of unprocessed residual heparinised blood would increase the aPTT by 15 %

Read more

Summary

Introduction

Autologous blood transfusion is a common technique in cardiac surgery to directly re-infuse residual blood from the cardiopulmonary bypass (CPB) circuit to the patient. The objective of this study was to evaluate the effects of reinfusion of unprocessed residual pump blood on the coagulation system after separation from the CPB circuit and reversal of systemic heparin with protamine. After the reinfusion of unprocessed residual pump blood there were decreases in the mean aPTT (effect size 6 s; SD: 6.05; p < 0.0001) and thrombin time (effect size 4.08 s; SD: 9.7; p = 0.01). Iyer et al BMC Res Notes (2016) 9:61 that the reinfusion of heparinised autologous blood administered after separation from the CPB circuit and complete reversal of systemic heparin with protamine, leads to prolongation of the common laboratory plasma based measurement of coagulation and derangements of the normal viscoelastic clotting properties of blood as measured by thromboelastography

Objectives
Methods
Results
Discussion
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.