Abstract

The conventional fatigue design codes was formulated based on the data from test stress cycles less than 1 × 10 7. Most of them could not be applied for welded structures serviced in the ultra-long life region so the new recommendations were discussed. The method of ultrasonic peening treatment (UPT) was introduced in this thesis as a post-weld treatment to improve the fatigue strength of the welded structures. The fatigue behavior of welded structures in the ultra-long life region was investigated using an ultrasonic fatigue test machine under two post-weld treatment states: the as-welded and the UPT. Discussion had also been made about the fracture mechanism on the UPT joints in ultra-long life fatigue test.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.