Abstract
In an HTS magnet consisting of pancake windings, an air gap between the pancake windings can be used to increase the central magnetic field because the air gap increases the critical current of pancake windings. The effects of an air gap on the central magnetic field of an HTS magnet are discussed in this paper according to the various number of turns and also to the number of pancake windings. Results of calculation show the air gap could increase the central magnetic field and the field uniformity simultaneously. The optimum air gap which maximized the central magnetic field was about 4 mm at eight pancake windings and 50 turns per pancake winding. The central magnetic field increased 6.2% from 0.225 T (no air gap) to 0.239 T (4 mm air gap) at that case.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.