Abstract

The measurement of the Impact Insulation Class (IIC) rating of any floor/ceiling construction requires the use of a certified laboratory space. In a recent investigation into the IIC rating of a new floor system, several tests were conducted in a certified laboratory. In many tests, the IIC rating was controlled by the 100-Hz 1/3-octave frequency band, despite changes in the floor/ceiling construction. The base floor/ceiling construction included a wood structural floor on open-web wood joists and a GWB ceiling below. This paper will investigate the possibility that room resonances influenced the IIC ratings of the several floor systems tested. These data will be compared with IIC data collected for the same floor construction with the GWB ceiling removed. The removal of the GWB ceiling increased the receiver room volume and exposed the glass fiber insulation to the receiver room, thus eliminating the control of the 100-Hz 1/3-octave band over the IIC rating.