Abstract
This paper examines the effects of using O 2, Ar and He process gasses during the treatment of the ordinary Portland cement (OPC) surface of concrete with a high-power diode laser (HPDL). The study revealed that, depending on the shield gas used, distinct difference existed in the surface condition of the concrete after HPDL treatment. In particular, the use of O 2 as the shield gas was seen to result in glazes with far fewer microcracks and porosities than those generated with either Ar or He shield gases. Such differences were found to be due to the smaller O 2 gas molecules dissolving molecularly into the open structure of the HPDL-generated glaze on the OPC surface of concrete and react with the glass network to increase the fluidity of the melt. This in turn was also seen to affect the cooling rate and therefore the tendency to generate microcracks.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.