Abstract
BackgroundMeasurement of work of breathing (WOB) during mechanical ventilation is essential to assess the status and progress of intensive care patients. Increasing ventilator WOB is known as a risk factor for ventilator-induced lung injury (VILI). In addition, the minimization of WOB is crucial to facilitate the weaning process. Several studies have assessed the effects of varying inspiratory flow waveforms on the patient’s WOB during assisted ventilation, but there are few studies on the different effect of inspiratory flow waveforms on ventilator WOB during controlled ventilation.MethodsIn this paper, we analyze the ventilator WOB, termed mechanical work (MW) for three common inspiratory flow waveforms both in normal subjects and COPD patients. We use Rohrer’s equation for the resistance of the endotracheal tube (ETT) and lung airways. The resistance of pulmonary and chest wall tissue are also considered. Then, the resistive MW required to overcome each component of the respiratory resistance is computed for square and sinusoidal waveforms in volume-controlled ventilation (VCV), and decelerating waveform of flow in pressure-controlled ventilation (PCV).ResultsThe results indicate that under the constant I:E ratio, a square flow profile best minimizes the MW both in normal subjects and COPD patients. Furthermore, the large I:E ratio may be used to lower MW. The comparison of results shows that ETT and lung airways have the main contribution to resistive MW in normals and COPDs, respectively.ConclusionThese findings support that for lowering the MW especially in patients with obstructive lung diseases, flow with square waveforms in VCV, are more favorable than decelerating waveform of flow in PCV. Our analysis suggests the square profile is the best choice from the viewpoint of less MW.
Highlights
Measurement of work of breathing (WOB) during mechanical ventilation is essential to assess the status and progress of intensive care patients
Using the term of mechanical work (MW) instead of the energy delivered to the respiratory system by ventilator per breath, mechanical power (MP) is MW multiplied by respiratory rate (RR) [7]
Since in most intensive care patients, flow resistance is increased due to airway obstruction and/or tracheal intubation, there are numerous attempts to minimize WOB
Summary
Measurement of work of breathing (WOB) during mechanical ventilation is essential to assess the status and progress of intensive care patients. The concept of mechanical power (MP) as a measure for the development of ventilator-induced lung injury (VILI) is a promising idea [5]. Using the term of mechanical work (MW) instead of the energy delivered to the respiratory system by ventilator per breath (ventilator WOB), MP is MW multiplied by respiratory rate (RR) [7]. MP is defined as a unified index for measuring the risk of VILI in patients under mechanical ventilation [7]. The flow-dependent component of the MW is work done by dissipative resistance resulting from the frictional stresses on the gas flow in the airways
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.