Abstract
Abstract Emissions from masonry heaters and sauna stoves were studied. In the sauna stove the production of organic gaseous carbon (OGC) at 10 gC kg −1 (per kilogram of fuel), carbon monoxide (CO) at 55 g kg −1 , fine particle mass (PM 1 ) at 5 g kg −1 and number emissions (N) at 1.8 × 10 15 kg −1 was higher than in other measured appliances. In a modern technology masonry heater with a unique grate, the emissions were very low: 0.4 gC kg −1 OGC, 14 g kg −1 CO and 0.7 g kg −1 PM 1 . Conventional masonry heaters, using small logs, clearly produced higher emissions when compared to using large logs. Doubling the fuel load caused emission factors to increase by up to 4- times (OGC), except for the number emission, which decreased from 4.0 × 10 14 to 2.0 × 10 14 kg −1 . From the conventional masonry heater 90% of the PM was emitted during the firing phase. Its combustion process is different to that in stoves or conventional open fireplaces. The insufficient supply of air, due to too fast pyrolysis, and increased ash release, due to the high combustion temperature, are the main parameters which cause high particle and gas emissions in masonry heaters and sauna stoves.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.