Abstract

The purpose of this work was to study the effects of background noise and hearing attenuation associated with earplugs on three physiological measures, assumed to be markers of effort investment and arousal, during interactive communication. Twelve pairs of older people (average age of 63.2 years) with age-adjusted normal hearing took part in a face-to-face communication to solve a Diapix task. Communication was held in different levels of babble noise (0, 60, and 70 dBA) and with two levels of hearing attenuation (0 and 25 dB) in quiet. The physiological measures obtained included pupil size, heart rate variability, and skin conductance. In addition, subjective ratings of perceived communication success, frustration, and effort were obtained. Ratings of perceived success, frustration, and effort confirmed that communication was more difficult in noise and with approximately 25-dB hearing attenuation and suggested that the implemented levels of noise and hearing attenuation resulted in comparable communication difficulties. Background noise at 70 dBA and hearing attenuation both led to an initial increase in pupil size (associated with effort), but only the effect of the background noise was sustained throughout the conversation. The 25-dB hearing attenuation led to a significant decrease of the high-frequency power of heart rate variability and a significant increase of skin conductance level, measured as the average z value of the electrodermal activity amplitude. This study demonstrated that several physiological measures appear to be viable indicators of changing communication conditions, with pupillometry and cardiovascular as well as electrodermal measures potentially being markers of communication difficulty.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call