Abstract
According to the General Statistics Office (Ministry of Planning and investment) collaborated with the United Nations Children’s Fund in Viet Nam, from 2016 to 2017, there were nearly 5 million households which had disabilities in the country. The proportion of people with disabilities who were over 2 years old accounted for 7% of the population. Another statistic is based on the Christopher & Dana Reeve Foundation report in 2013, about 5.4 million Americans suffer from disability [2]. Many research works, therefore, have been built with the aim of improving the ability of movement and communication, based on biomedical signals, especially the Brain-Computer Interface (BCI) system. BCI is a technology that enables the use of the brain’s neural activity to communicate with others or to control machines, artificial limbs, or robots without direct physical movements. BCI based on electroencephalogram (EEG) can be applied to the disabled individual system. In recent years, there are many people suffering from the loss of all voluntary muscle control in Viet Nam. Therefore, they really need alternative interaction methods to control their behaviors with external environment. Thanks to the development of Brain-Computer interfaces and the EEG headset have been helping people who are incapable of any motion for function can communicate with the external world, due to the P300 signal. As the important consideration to discover which factors affect the accuracy of BCI system to improve communication quality for the ability of disabled people, we decide to discover the impact of character matrix size and inter stimulus interval on event related potential. The duration of the inter stimulus interval (ISI) between targets is set at 187,5 ms and 125 ms for two different matrix sizes 3x3 and 6x6. The results provide that the largest amplitudes of P300 waveforms occur remarkably at the occipital and frontal channels and are higher than in 6x6 letter matrix compared with 3x3 matrix. The different matrix size and ISI does not affect on the appearance time of the P300 signal, and it is in the range 235-244 ms after stimulation. These good results promise to help other researches to build a perfect experimental procedure in real assistance application for using BCI – P300 systems.
Highlights
Taccording to the General Statistics Office (Ministry of Planning and investment) collaborated with the United Nations Children’s Fund in Viet Nam, from 2016 to 2017, there were nearly 5 million households which had disabilities in the country
Our group does experiments in conditions of 2 matrixes 3x3 and 6x6 and the duration of the inter stimulus interval (ISI) between targets is set at [187,5] ms and 125 ms to examine appearance time of P300 and its amplitude to optimise experiemental system and algorithm in Brain Computer Interface (BCI)
After the noise filter is completed, it becomes easier to check the appearance of the desired P300 signal by plotting a multi-channel graph, the recording information including wave shape, time of P300
Summary
Taccording to the General Statistics Office (Ministry of Planning and investment) collaborated with the United Nations Children’s Fund in Viet Nam, from 2016 to 2017, there were nearly 5 million households which had disabilities in the country. Science & Technology Development Journal – Engineering and Technology, 3(SI):SI131-SI140 suitable number of letters and words in realistic controlling model It is a reasonable choice for classification by high accuracy. While matrix 6x6 is a basic option in most of experiments aiming to detect P300 waveform This is because the probability of the target being flashed was 0.17, and such improbable events had been shown to produce robust P300s 9. Our group does experiments in conditions of 2 matrixes 3x3 and 6x6 and the duration of the inter stimulus interval (ISI) between targets is set at [187,5] ms and 125 ms to examine appearance time of P300 and its amplitude to optimise experiemental system and algorithm in BCI. Our group used EMOTIV EPOC contains 14 Electroencephalogram (EEG) channels and the sampling rate at 128 Hz to collect EEG signals of vonlunteers.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Science & Technology Development Journal - Engineering and Technology
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.