Abstract

A description is given of a 10-m open-area test site (OATS) for measuring radiated electromagnetic emissions from computing devices. The test site, located in southeastern Minnesota, is described. Its performance is analyzed by comparing horizontal and vertical site attenuation measured at the site to a theoretical model. The impact of the ground screen is examined by analyzing site attenuation data from two OATSs. The model developed by A.A. Smith et al. (1982) is used. The effects of the ground screen's size and the termination of its edges are discussed. Three methods of edge termination are examined. The vertical polarization is more sensitive to imperfections in the ground screen; hence, the bulk of the data presented is from vertically polarized site attenuation measurements. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.