Abstract

Constant flux virus filtration experiments were conducted to evaluate minute virus of mice retention behavior of four commercial virus filters for continuous bioprocessing applications. Fluxes chosen were guided by the Peclet number and the processing logistics as well as based on the filter characteristics. At the low flux condition of 5 (LMH) when diffusive force dominates, a significant breakthrough was observed for all the filtrate fractions for the filtration of a low fouling monoclonal antibody for three of the four filters. When both diffusive and convective forces are equally important at 40 LMH, virus breakthrough in buffer chase was observed only in one of the four filters investigated. When convective force dominates at 60 LMH or above, a high degree of virus clearance was observed for all three parvovirus filters investigated. Our work shed light on virus clearance during constant flux virus filtration for future continuous biomanufacturing.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.