Abstract

The influence of a variety of background gasses on the failure rate of gated field emitter arrays has been investigated. The effects of argon, helium, nitrogen and xenon were investigated, with pressures ranging from 1/spl times/10/sup -8/ Torr to 1/spl times/10/sup -4/ Torr. The gated field emitter arrays were operated in DC and pulsed emission modes. The failure rate of gated field emitter is a very strong function of the type of background gas, its pressure and whether the array was operated in a pulsed or DC bias mode. As expected, the failure rate for all gases increased rapidly as the background pressure increased, but was substantially different for the various gases. The failure rate of arrays increased rapidly as the electron impact ionization cross section of the background gas decreased. The large reduction in failure rates due to operation in a pulsed mode as compared to a DC mode of operation as previously seen for experiments without a background gas was also evident for all background gases tested.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.