Abstract
Seven fresh cadaveric specimens were used to determine the loss of forearm rotation with varying distal radius fracture malalignment patterns. Uniplanar malunion patterns consisting of dorsal tilt, radioulnar translation, or radial shortening were simulated by creating an osteotomy at the distal end of the radius, orienting the distal fragment position using an external fixator, and maintaining the position with wedges and a T-plate. Rotation of the forearm was produced by fixing the elbow in a flexed position and applying a constant torque to the forearm using deadweights. Forearm rotation was measured with a protractor. Dorsal tilt to 30 degrees and radial translation to 10 mm led to no significant restriction in forearm pronation or supination ranges of motion. A 5-mm ulnar translation deformity resulted in a mean 23% loss of pronation range of motion. Radial shortening of 10 mm reduced forearm pronation by 47% and supination by 29%.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.