Abstract

Trochanteric soft tissue thickness (TSTT) is a protective factor against fall-related hip fractures. This study's objectives were to determine: (1)the influence of body posture on TSTT and (2)the downstream effects of TSTT on biomechanical model predictions of fall-related impact force (Ffemur) and hip fracture factor of risk. Ultrasound was used to measure TSTT in 45 community-dwelling older adults in standing, supine, and side-lying positions with hip rotation angles of -25°, 0°, and 25°. Supine TSTT (mean [SD] = 5.57 [2.8]cm) was 29% and 69% greater than in standing and side-lying positions, respectively. The Ffemur based on supine TSTT (3380 [2017]N) was 19% lower than the standing position (4173 [1764]N) and 31% lower than the side-lying position (4908 [1524]N). As factor of risk was directly influenced by Ffemur, the relative effects on fracture risk were similar. While less pronounced (<10%), the effects of hip rotation angle were consistent across TSTT, Ffemur, and factor of risk. Based on the sensitivity of impact models to TSTT, these results highlight the need for a standardized TSTT measurement approach. In addition, the consistent influence of hip rotation on TSTT (and downstream model predictions) support its importance as a factor that may influence fall-related hip fracture risk.