Background: The coronavirus disease 2019 (COVID-19) pandemic has challenged the ability to do face-to-face training on advanced diabetes management technologies. In the United States, Medtronic Diabetes shifted from occasional to 100% virtual training on all diabetes devices in mid-March 2020. We studied the outcomes of virtual training on the MiniMed™ 670 G hybrid closed-loop system in type 1 diabetes.Methods: From March 20, 2020, to April 22, 2020 (intra-COVID-19), virtual training on the MiniMed 670 G system was completed using Zoom with satisfaction captured through online post-training surveys. Training efficiency was measuring by the days between the date of product shipment and the date of the first and final trainings. Patient satisfaction with training on the MiniMed 670 G was determined by Net Promotor Score® (NPS®). Uploads from CareLink™ Personal and CareLink Professional and calls to the Medtronic 24-h technical support team requesting educational/software assistance and/or help with health care provider telehealth visits were recorded. Continuous glucose monitoring (CGM) results were measured using the CareLink Personal database. All results except for the Zoom satisfaction survey were compared with data from January 20, 2020, to February 22, 2020, (Pre-COVID-19) when training was performed in-person.Results: The CGM metrics were comparable between pre- and intra-COVID-19 training. The Zoom video conferencing application had 98% satisfaction. The NPS rose from 78 to 84. The time between the pump shipment and the first and last (automode) training was significantly reduced from 14 ± 7 days to 11 ± 5 days (P < 0.001) and from 19 ± 7 days to 15 ± 15 days (P < 0.01), respectively. There was a decrease in the calls for educational assistance to the technical support team but an increase in requests for login and software installation support.Conclusions: Virtual training of individuals with diabetes on the MiniMed 670 G system resulted in high satisfaction and short-term glycemic results comparable with in-person training.

Highlights

  • The coronavirus disease 2019 (COVID-19) pandemic has upended the nonmedical and medical worlds in many ways

  • We studied the outcomes of virtual training on the MiniMedÔ 670 G hybrid closed-loop system in type 1 diabetes

  • For those managing their diabetes with closed-loop systems, many of their health care providers (HCPs) expect that their patients would stop using continuous glucose monitoring (CGM) before stopping pump therapy if they lost their job

Read more

Summary

Introduction

The coronavirus disease 2019 (COVID-19) pandemic has upended the nonmedical and medical worlds in many ways. Supply chains have remained intact,2 55% of people with diabetes are concerned about obtaining their diabetes supplies.3 For those managing their diabetes with closed-loop systems, many of their health care providers (HCPs) expect that their patients would stop using continuous glucose monitoring (CGM) before stopping pump therapy if they lost their job.. Methods: From March 20, 2020, to April 22, 2020 (intra-COVID-19), virtual training on the MiniMed 670 G system was completed using Zoom with satisfaction captured through online post-training surveys. All results except for the Zoom satisfaction survey were compared with data from January 20, 2020, to February 22, 2020, (Pre-COVID-19) when training was performed in-person. Conclusions: Virtual training of individuals with diabetes on the MiniMed 670 G system resulted in high satisfaction and short-term glycemic results comparable with in-person training

Methods
Results
Conclusion