Abstract

Syringes with attached needles (termed fixed low dead space syringes [LDSS]) retain less blood following injection than syringes with detachable needles, but evidence on them reducing blood-borne virus transmission among people who inject drugs (PWID) is lacking. Utilizing the UK Unlinked Anonymous Monitoring cross-sectional bio-behavioral surveys among PWID for 2016/18/19 (n = 1429), we showed that always using fixed LDSS was associated with 76% lower likelihood (adjusted odds ratio = 0.24, 95% confidence interval [CI]: .08–.67) of recent hepatitis C virus infection (RNA-positive and antibody-negative) among antibody-negative PWID compared to using any syringes with detachable needles.