Abstract

Dentin hypersensitivity is a frequent oral condition among patients suffering from gingival recession. Recent studies have suggested that photobiomodulation has the potential to reduce inflammation and relieve pain. The present study aims to assess the effectiveness of a new design of photobiomodulation toothbrush with specific irradiation parameters as a homecare device in treating dentin hypersensitivity and to compare its therapeutic effect with that of fluoride varnish. Thirty patients with gingival recession and dentin hypersensitivity were selected and randomly assigned to three groups of equal size: fluoride varnish, photobiomodulation, and the combination. Dentin pain and hypersensitivity were measured using visual analog scale (VAS) by two distinct tests: the contact test with a periodontal probe and the air blast test on the areas of gingival recession and denuded root; once at baseline and again one month after the initial application of treatments. Laser irradiation was carried out at the wavelength of 660 nm in CW with an output power of 40 mW for 30 seconds per spot (1.2 J per spot, 6 J/cm2 energy density, and 200 mW/cm2 power density), perpendicularly to denuded root surfaces in non-contact mode. A significant reduction in dentin pain and hypersensitivity was observed in all three groups. However, the reduction was significantly greater in the combination group. At-home treatment of dentin hypersensitivity with photobiomodulation toothbrush is a convenient, safe, and effective method for the management of dentin hypersensitivity.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call