Abstract
In this work the activity of protons directly at the solid–liquid interface during a heterogeneous reaction is demonstrated without introducing any pH measurement device, in non-buffered and buffered solutions. Due to a simple approach we can experimentally demonstrate the relation between reaction rate and surface pH directly from the cyclic voltammograms. Clearly, the pH at a solid–liquid interface can be quite different from the bulk in unbuffered or insufficiently buffered solutions even at moderate reaction rates, in particular in the pH range of 4 to 10. However, at the given mass-transport conditions, well controlled by a rotating disk electrode, a buffer concentration of 10 − 2 M is already sufficient to pin the surface pH to the bulk value at reaction rates of up to 1 mA cm − 2 .
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.