Abstract

Objective:To retrospectively analyze the clinical impact on stereotactic body radiation therapy (SBRT) for hepatocellular carcinoma (HCC) located at lung–liver boundary due to the use of Acuros XB algorithm (AXB) in replacement of anisotropic analytical algorithm (AAA).Methods:23 SBRT volumetric modulated arc therapy (VMAT) plans for HCC located at lung–liver boundary were calculated using AAA and AXB respectively with the same treatment parameters. The dose–volume data of the planned target volumes (PTVs) were compared. A published tumour control probability (TCP) model was used to calculate the effect of dosimetric difference between AAA and AXB on tumour control probability.Results:For dose calculated by AXB (Dose to medium), the D95% and D98% of the PTV were on average 2.4 and 3.1% less than that calculated by AAA. For dose calculated by AXB (dose to water), the D95% and D98% of the PTV were on average 1.8%, and 2.7% less than that calculated by AAA. Up to 5% difference in D95% and 8% difference in D98% were observed in the worst cases. The significant decrease in D95% calculated by AXB compared to AAA could result in a % decrease in 2 year TCP up to 8% in the worst case (from 46.8 to 42.9%).Conclusion:The difference in dose calculated by AAA and AXB could lead to significant difference in TCP for HCC SBRT located at lung–liver boundary region.Advances in knowledge:The difference in calculated dose and tumour control probability for HCC SBRT between AAA and AXB algorithm at lung–liver boundary region was compared.