Abstract

The surrounding conditions of the shielding concrete, (moisture and temperature), affect the water content within it, and therefore, the attenuation coefficient of the concrete. In this study, the impact of changing the amount of water, in four types of local candidate shielding concretes was investigated. The concrete attenuation coefficient of gamma-rays has been identified experimentally and computationally using the MCNP-4C code. The results show a significant decrease in the attenuation coefficient of each the four concrete samples due to the water losses, especially between 20- 100 oC. Acceptable compatibility was noticed between the measured and calculated results of the attenuation coefficient of the studied concrete samples.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.