Abstract
Heat transfer characteristics of air-assistant water jet impingement was experimentally investigated under a fixed water flow rate condition. Water and air were used as the test fluids. The effects of volumetric quality (β=0–0.9) on the Nusselt number and pressure were considered. The results showed that the stagnation Nusselt number increased with volumetric quality, attained a maximum value at around 0.8 of the volumetric quality, and then decreased. The stagnation Nusselt number of the air-assistant water jet impingement is governed by the stagnation pressure. Based on the experimental results, a new correlation for the normalized stagnation Nusselt number is developed as a function of the normalized stagnation pressure alone. In addition, the lateral variation of Nusselt number is governed by hydraulic jump radius.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.