Abstract

Flow boiling flow patterns in four circular tubes with internal diameters of 1.10, 2.01, 2.88 and 4.26 mm were investigated in the present project. The experiments were conducted in vertical upward two-phase flow using R134a as the working fluid. The observed flow patterns include dispersed bubble, bubbly, confined bubble, slug, churn, annular and mist flow. The flow characteristics in the 2.88 and 4.26 mm tubes are similar to those typically described in normal size tubes. The smaller diameter tubes, 1.10 and 2.01 mm, exhibit strong “small tube characteristics” as described in earlier studies. The sketched flow maps show that the transition boundaries of slug-churn and churn-annular depend strongly on diameter. On the contrary, the dispersed bubble to churn and bubbly to slug boundaries are less affected. The transition boundaries are compared with existing models for normal size tubes showing poor agreement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.