Abstract
Natural convection experiments inside a vertical cylindrical cavity were performed for Rayleigh numbers of 1.08 × 10 10–2.11 × 10 13 and for four different geometrical arrangements: both-open (pipe-shape), bottom-closed (cup-shape), top-closed (cap), and both-closed (cavity) cylinders. A copper electroplating system was employed for the measurements of heat transfer rates using analogy concept. The lids used to close top or bottom were adiabatic; i.e. inactive surfaces in the electrodeposition experiments. The bottom-closed cavity showed the highest heat transfer rates and then followed both-closed, both-open, top-closed ones in both laminar and turbulent flows. The results were in satisfactory agreements with the existing correlations developed for similar geometrical configurations and the empirical correlations were derived. The numerical simulations were carried out using the FLUENT 6.2 to explain the measured results. The analysis of the streamline and the local Nusselt number gave explanations for the observation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.