Abstract
Both tidal volume and effective blood volume may affect the variation in the arterial pressure waveform during mechanical ventilation. The systolic pressure variation (SPV), which is the difference between the maximal and minimal systolic pressure values following one positive pressure breath was analyzed in 10 anesthetized and ventilated dogs, during ventilation with tidal volumes of 15 and 25 ml/kg. The dogs were studied during normovolemia, hypovolemia (after bleeding of 30% of estimated blood volume) and hypervolemia (after retransfusion of shed blood with additional 50 ml/kg of plasma expander). The SPV reflected hemodynamic changes and was maximal during hypovolemia and minimal during hypervolemia. Unlike all other hemodynamic parameters it was also affected by the tidal volume and significantly increased at higher tidal volumes during each volume state. We conclude that the SPV and its components are useful parameters in evaluating the intravascular volume state. They also reflect the magnitude of the tidal volume employed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.