Abstract

The tibia index (TI) is commonly used to predict leg injury based on measurements taken by an anthropomorphic test device (ATD). The TI consists of an interaction formula that combines axial loading and bending plus a supplemental compressive force criterion. Current ATD lower limbs lack geometric biofidelity with regard to tibial curvature and fibular load-sharing. Due to differences in tibial curvature, the midshaft moments induced by axial loading are different in humans and ATDs. Midshaft tibial loading in the human is also reduced by load-sharing through the fibula, which is not replicated in current ATDs. In this study, tibial curvature and fibular load-sharing are quantified through CT imaging and biomechanical testing, and equations are presented to correct ATD measurements to reflect the loading that would be experienced by a human tibia.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.