Abstract
This study describes a laboratory investigation of the influence of thiosemicarbazide (TSC) on the corrosion of reinforcing steel and the compressive strength of concrete. The effect of TSC on the corrosion resistance of steel reinforced concrete was evaluated by carrying out electrochemical tests in NaCl and NaCl + TSC solutions for 60 days. Polarisation resistance ( R p) values of TSC added reinforced concrete were much higher than those without TSC. Similarly, AC impedance spectra revealed that the resistance of TSC mixed electrodes were also quite higher than those without. The compressive strength of concrete specimens containing TSC was measured and an increase of 20–25% was observed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.