Abstract
The impact of enclosure aspect ratio and different thermophysical properties of fluids on heat transfer were investigated in rectangular enclosure with 3x3 array of flush-mounted chips placed on the front vertical wall with constant temperature and cooled by the opposite wall. To study heat transfer inside the enclosure simulations were done for four enclosure aspect ratios(A=1.0, 5.0, 7.5, 20.0) and five fluids(air, water, FC-40, FC-72, FC-88). Numerical results show that the highest velocities are in the air while low velocities have been noticed in the water, FC-40, FC-72, FC-88. The maximum air velocities for the W component are obtained precisely at a height of Z= 5.5. It is observed that when enclosure aspect ratio decreases, the fluid velocity increases. Maximum Nu number was when enclosure was filled with dielectric fluids FC-72 and FC-88, and minimal was found in the air. To ensure that chosen numerical methods, computer program was implemented correctly test task were completed. Good agreement is found between the results.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.