Abstract
Prosthetic impingement due to poor positioning can limit the range of motion of the hip after total hip arthroplasty. In this study, a computer model was used to determine the effects of the positions of the acetabular and femoral components and of varying head-neck ratios on impingement and range of motion. A three-dimensional generic hip prosthesis with a hemispherical cup, a neck diameter of 12.25 millimeters, and a head size ranging from twenty-two to thirty-two millimeters was simulated on a computer. The maximum range of motion of the hip was measured, before the neck impinged on the liner of the cup, for acetabular abduction angles ranging from 35 to 55 degrees and acetabular and femoral anteversion ranging from 0 to 30 degrees. Stability of the hip was estimated as the maximum possible flexion coupled with 10 degrees of adduction and 10 degrees of internal rotation and also as the maximum possible extension coupled with 10 degrees of external rotation. The effects of prosthetic orientation on activities of daily living were analyzed as well. Acetabular abduction angles of less than 45 degrees decreased flexion and abduction of the hip, whereas higher angles decreased adduction and rotation. Femoral and acetabular anteversion increased flexion but decreased extension. Acetabular abduction angles of between 45 and 55 degrees permitted a better overall range of motion and stability when combined with appropriate acetabular and femoral anteversion. Lower head-neck ratios decreased the range of motion that was possible without prosthetic impingement. The addition of a modular sleeve that increased the diameter of the femoral neck by two millimeters decreased the range of motion by 1.5 to 8.5 degrees, depending on the direction of motion that was studied. There is a complex interplay between the angles of orientation of the femoral and acetabular components. Acetabular abduction angles between 45 and 55 degrees, when combined with appropriate acetabular and femoral anteversion, resulted in a maximum overall range of motion and stability with respect to prosthetic impingement. During total hip arthroplasty, acetabular abduction is often constrained by available bone coverage, while femoral anteversion may be dictated by the geometry of the femoral shaft. For each combination of acetabular abduction and femoral anteversion, there is an optimum range of acetabular anteversion that allows the potential for a maximum range of motion without prosthetic impingement after total hip arthroplasty. These data can be used intraoperatively to determine optimum position.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: The Journal of Bone and Joint Surgery-American Volume
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.