Abstract

Biologic scaffolds composed of extracellular matrix are commonly used in a variety of surgical procedures. The Food and Drug Administration typically regulates biologic scaffolds as medical devices, thus requiring terminal sterilization prior to clinical use. However, to date, no consensus exists for the most effective yet minimally destructive sterilization protocol for biologic scaffold materials. The objective of the present study was to characterize the effect of ethylene oxide, gamma irradiation and electron beam (e-beam) irradiation on the material properties and the elicited in vivo remodeling response of a porcine dermal biologic scaffold. Outcome measures included biochemical, structural, and mechanical properties as well as cytocompatibility in vitro. In vivo evaluation utilized a rodent model to examine the host response to the materials following 7, 14, and 35days. The host response to each experimental group was determined by quantitative histologic methods and by immunolabeling for macrophage polarization (M1/M2). In vitro results show that increasing irradiation dosage resulted in a dose dependent decrease in mechanical properties compared to untreated controls. Ethylene oxide-treated porcine dermal ECM resulted in decreased DNA content, extractable total protein, and bFGF content compared to untreated controls. All ETO treated, gamma irradiated, and e-beam irradiated samples had similar cytocompatibility scores in vitro. However, in vivo results showed that increasing dosages of e-beam and gamma irradiation elicited an increased rate of degradation of the biologic scaffold material following 35days. Statement of SignificanceThe FDA typically regulates biologic scaffolds derived from mammalian tissues as medical devices, thus requiring terminal sterilization prior to clinical use. However, there is little data and no consensus for the most effective yet minimally destructive sterilization protocol for such materials. The present study characterized the effect of common sterilization methods: ethylene oxide, gamma irradiation and electron beam irradiation on the material properties and the elicited in vivo remodeling response of a porcine dermal biologic scaffold. The results of the study will aid in the meaningful selection of sterilization methods for biologic scaffold materials.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call