Abstract

Statement of Problem. It has been stated that reversible hydrocolloid impression material must be poured immediately to remain accurate. This may not be true with modern formulations of reversible hydrocolloid. The accuracy of the impression, if kept at 100% humidity for varying periods, may not be affected as critically as has been suspected. Purpose. The purpose of this study was to evaluate the effect of storage time in a 100% humidity environment on the accuracy of gypsum casts poured from a newer formulation of reversible hydrocolloid impressions. Material and Methods. With the use of a stainless steel master model, 5 standardized reversible hydrocolloid impressions were made for each time interval tested (n = 5). Impressions were made with the use of both Cartiloid blue syringe and Slate tray reversible hydrocolloid material (both manufactured by Van R) to simulate a common clinical protocol. Six groups, representing times at 0, 30, 60, 120, 180, and 210 minutes, were evaluated for a total of 30 specimens. Gypsum casts were measured with a traveling microscope, and dimensional changes were compared between groups with ANOVA and Tukey intervals (α=.05). Results. Measurements made up to and including the 60-minute storage time showed clinically acceptable distortion levels. These measurements were similar to the metal model and the gypsum casts poured at time 0 minutes. The only statistically significant difference between the gypsum cast and the metal master model was the distance between abutments at storage time 180 minutes (master model = 30.04 mm [SD 0.001]; gypsum casts = 29.944 mm [SD 0.076]). This difference was −91 μm (P=.002). In general, the gypsum abutments became wider and shorter with time. There was no significant difference between any gypsum abutment in regard to width or height when compared with the metal master model for all the storage times tested. However, as time increased, measurement became harder to accomplish, leading to a larger standard deviation and less reliable results. The distance between abutments remained relatively constant for storage times up to and including 60 minutes. For times longer than 60 minutes, the distance between abutments was reduced and more difficult to read. The distance between abutments at the 3-hour storage time was significantly different than the metal standard and time 0 gypsum casts. Conclusion. If a discrepancy of 78 mm (twice the 39 mm single margin opening) is clinically acceptable, then the results of this study show that this type of reversible hydrocolloid can be stored in 100% humidity for at least 60 minutes. (J Prosthet Dent 2001;86:244-50.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.